Thyroid nodule ultrasound is the first-line exam for characterizing palpable, incidental, and previously documented nodules. Most nodules are benign. The practical task is to complete a gland and nodal survey, describe each nodule with a standard lexicon, assign an ACR TI-RADS category, and apply size thresholds that separate follow-up from fine-needle aspiration.
Scanning Technique for Thyroid Nodule Ultrasound
Use a high-frequency linear transducer, typically around 10 MHz or higher. Lower the frequency or widen the field for a thick neck, large gland, or substernal extension. Position the patient supine with the neck mildly extended. Scan both lobes transversely and longitudinally, include the isthmus, and survey the lateral neck for abnormal nodes when a suspicious nodule is present.
- Document the largest nodule in each lobe and any smaller nodule with suspicious features.
- Record lobe, pole, and anterior or posterior location so comparison studies match.
- Color Doppler may show vascularity, but ACR TI-RADS does not assign points for flow.
- When suspicion is high, look for rounded, cystic, or calcified cervical nodes.
What to include in the report
For each relevant nodule, report three diameters, composition, echogenicity relative to adjacent thyroid, shape, margin, and echogenic foci. Mention prior studies when growth or stability would change management.
Measurements and Size Thresholds
Measure each nodule in three orthogonal planes. ACR TI-RADS applies cutoffs to the maximum diameter of the entire nodule, not the solid component alone. Match the prior plane on follow-up, because small caliper shifts can cross an FNA threshold.
Commonly cited ACR TI-RADS size guidance includes:
- TR1 (0 points) and TR2 (2 points): no FNA based on TI-RADS size criteria.
- TR3 (3 points): FNA at 2.5 cm or larger; follow-up at 1.5 cm or larger.
- TR4 (4 to 6 points): FNA at 1.5 cm or larger; follow-up at 1.0 cm or larger.
- TR5 (7 points or more): FNA at 1.0 cm or larger; follow-up at 0.5 cm or larger.
ATA sonographic patterns, EU-TIRADS, and Korean TIRADS use different descriptors and cutoffs. Name the lexicon your practice reports and do not mix two systems in one impression.
ACR TI-RADS Scoring at the Scanner
ACR TI-RADS assigns points in five feature families, then maps the sum to TR1 through TR5. A companion article reviews TI-RADS categories and management thresholds in more depth. Score only the features you can see.
Composition and echogenicity
- Cystic or almost completely cystic: 0 points. Spongiform occupying nearly the entire nodule: 0 points. Mixed cystic and solid: 1 point. Solid or almost completely solid: 2 points.
- Anechoic: 0 points. Hyperechoic or isoechoic to parenchyma: 1 point. Hypoechoic: 2 points. Very hypoechoic (darker than strap muscle): 3 points.
Shape, margin, and echogenic foci
- Wider-than-tall: 0 points. Taller-than-wide, meaning anteroposterior diameter greater than transverse diameter on a transverse image: 3 points.
- Smooth or ill-defined margin: 0 points. Lobulated or irregular: 2 points. Extra-thyroidal extension: 3 points.
- None or large comet-tail artifacts: 0 points. Macrocalcifications: 1 point. Peripheral rim calcifications: 2 points. Punctate echogenic foci: 3 points.
Add the points. Zero is TR1, 2 is TR2, 3 is TR3, 4 to 6 is TR4, and 7 or more is TR5.
Ultrasound Features of Suspicious and Benign Nodules
No single gray-scale finding diagnoses thyroid cancer on ultrasound. Solid composition, marked hypoechogenicity, taller-than-wide shape, irregular margins, and punctate echogenic foci together raise suspicion and often produce a TR4 or TR5 score. Abnormal regional lymph nodes add concern even when the thyroid nodule is small.
Simple cysts, spongiform architecture, and large comet-tail artifacts typical of colloid usually support a benign or not-suspicious category. An isoechoic solid nodule scores 1 point for echogenicity and often falls in TR3 when other features are low risk. For protocol detail, see thyroid gland nodule ultrasound technique and TI-RADS features.
Pitfalls That Change TI-RADS Category
- Spongiform versus mixed cystic and solid. Scattered cysts in a mostly solid nodule are not spongiform.
- Comet-tail artifacts versus punctate echogenic foci. Large comet tails favor colloid. Tiny non-shadowing punctate foci in a solid hypoechoic nodule score 3 points.
- Shape on the wrong view. Taller-than-wide is defined on a transverse image. A longitudinal tall appearance does not receive 3 points.
- Ill-defined is not irregular. Do not award margin points for a hazy edge in Hashimoto thyroiditis.
- Hidden interiors and pseudonodules. If rim calcium hides composition or echogenicity, state the limitation. Confirm geographic hypoechoic thyroiditis in two planes. A capsular bulge with an intact capsule is not extra-thyroidal extension.
Complete the survey, measure in three planes, score visible features only, and apply one lexicon. When shadowing or thyroiditis limits assessment, describe the limitation rather than forcing a low score. IAME offers accredited ultrasound CME courses on thyroid and neck imaging for clinicians who want additional structured case review.
Frequently Asked Questions
Is a nodule on your thyroid normal?
Thyroid nodules are common incidental findings, and prevalence increases with age. Most are benign, but each still needs lexicon features and, when size and category warrant it, follow-up or FNA.
What is the silent warning of thyroid cancer?
There is no reliable symptom that flags early thyroid cancer. Many differentiated cancers are asymptomatic, so suspicious gray-scale features, growth, and abnormal cervical nodes matter more than a characteristic pain pattern.
Can a thyroid nodule cause a sore throat?
Small nodules rarely cause isolated sore throat. Large goiter can cause pressure or dysphagia, and thyroiditis can cause pain, but the symptom is nonspecific.
What does an isoechoic thyroid nodule signify?
Isoechoic means the solid tissue matches adjacent parenchyma in brightness and scores 1 point in ACR TI-RADS. An isoechoic solid nodule with otherwise low-risk features is often TR3. Composition, shape, margins, and echogenic foci still decide the category.