A renal ultrasound is often the first-line study for flank pain, hydronephrosis, unexplained azotemia, hematuria, and suspected cystic or solid masses. It is rapid, uses no ionizing radiation, and shows morphology, collecting-system dilatation, and Doppler flow in real time. This scanner-ready protocol for the native kidneys covers positioning, required grayscale and Doppler views, commonly cited size and resistive-index ranges, and artifacts that mimic stones, obstruction, or masses. It supports clinical judgment. It does not replace a dedicated renal-artery stenosis or transplant examination.
Patient Positioning and Scanning Technique
Use a curved-array transducer in the 2 to 5 MHz range for most adults, and a higher-frequency linear or compact convex transducer when the patient is thin or cortical detail matters. Approach the right kidney through the liver in the anterior or mid-axillary line. Approach the left kidney through the spleen or a posterolateral intercostal window. Deep inspiration often clears the costal margin. If gas or ribs hide a pole, roll the patient into the contralateral decubitus position or scan prone from the back. Fill the field of view with the kidney, place a single focal zone at the sinus, use harmonics, and match gain from side to side before you call a difference in echogenicity.
Required Grayscale Views for Renal Ultrasound
Record each kidney in two orthogonal planes so poles, contour, and sinus are documented, not only a mid-kidney still frame.
- Longitudinal cine through the upper pole, interpolar kidney, and lower pole
- Transverse cine from upper pole to lower pole
- Static longitudinal image with bipolar length measured on the longest axis
- Transverse hilar image showing cortex, sinus, and vessels when visible
- Focused images of any cyst, mass, calculus, or dilated calyx
- Comparison of cortical echogenicity with the liver on the right and the spleen on the left
- Bladder in two planes when obstruction, hematuria, or lower-tract symptoms are in the indication
Measuring length and calling hydronephrosis
Measure length on the true longest bipolar axis. A difference of more than about 1.5 to 2 cm between native kidneys is often treated as asymmetry after you account for rotation, body habitus, and prior surgery. Mild sinus separation can be physiologic with hydration or a full bladder. Call hydronephrosis when dilated calyces communicate with a dilated pelvis, show the ureteropelvic junction when you can, and obtain a post-void bladder view if that separation might be transient.
Anatomy, Normal Variants, and Mimics
Name the variant before you name a mass or a scar.
- Hypertrophied column of Bertin: sinus-indenting tissue that is isoechoic to cortex, continuous with a column, and without a contour bulge. Color Doppler usually shows arcuate vessels coursing through it.
- Dromedary hump: lateral cortical bulge on the left, typically opposite the spleen, with normal echotexture.
- Persistent fetal lobulation: indentations between pyramids. Scars indent over a calyx.
- Junctional parenchymal defect: echogenic triangular or linear defect, often anterior and upper interpolar, continuous with sinus fat.
- Extrarenal pelvis: prominent pelvis outside the sinus with non-dilated calyces.
- Duplex system: two sinus complexes. Look for upper-pole dilatation or a ureterocele when the history fits.
If a kidney is missing from the fossa, survey the pelvis and midline for ectopia, horseshoe kidney, or crossed fused ectopia.
Normal Size and Resistive-Index Ranges
Published values differ by population, sex, height, and age. Use ranges and contralateral comparison rather than a single cutoff.
- Adult bipolar length is commonly cited around 9 to 13 cm. Many practices review lengths below about 9 cm or above about 13 to 14 cm in light of body size.
- Cortical thickness is often described as about 7 to 10 mm or greater. Focal or clearly asymmetric thinning is more persuasive than a borderline global number.
- Parenchymal thickness from capsule to sinus is frequently about 1.5 to 2.0 cm in adults, with wide variation.
- Intrarenal resistive index in native kidneys is frequently considered normal below 0.70. Values of 0.70 or higher are nonspecific and occur with medical renal disease, obstruction, hypotension, and older age. Report the number and the context rather than equating an elevated RI with one diagnosis.
Pediatric length follows age and height. Do not apply adult cutoffs to children.
Color and Spectral Doppler
Add color Doppler to confirm hilar flow, to assess a suspected column of Bertin or mass, and to look for twinkle at a bright sinus focus. For a routine native exam, sample interlobar or arcuate arteries in the upper, mid, and lower kidney. Use a small gate, keep the beam as parallel to flow as anatomy allows, and calculate RI as (peak systolic velocity minus end-diastolic velocity) divided by peak systolic velocity.
Renal-artery duplex for stenosis is a separate study that needs fasting, origin-to-hilum imaging of the main renal arteries, and dedicated velocity criteria. Native Doppler also differs from ultrasound evaluation of the renal transplant, which uses different windows, anastomoses, and thresholds.
Pitfalls That Mimic Stones, Hydronephrosis, or Masses
Stones. Sinus fat is echogenic and may seem to shadow. A clean acoustic shadow and twinkle support a calculus, but twinkle changes with color-write priority and gain and is not specific. Tiny stones may be occult. See renal stone findings, shadowing, and pitfalls for a focused review.
Hydronephrosis. Parapelvic cysts, an extrarenal pelvis, hilar vessels, and prominent pyramids can mimic a dilated system. Color Doppler separates vessels from urine. Cysts do not connect to a shared pelvis. Simple-cyst criteria and complex features are covered in renal cysts ultrasound: simple-cyst criteria and Bosniak features.
Masses and other traps. Column of Bertin, dromedary hump, and lobulation are the usual mass mimics. A true mass typically distorts contour or sinus, differs in echogenicity, and displaces rather than transmits arcuate vessels. Isoechoic tumors are missed if the entire contour is not scanned in two planes. Rib and refraction shadows can imitate a stone or scar. Gas hides the left upper pole more often than the right. Increased cortical echogenicity is seen in medical renal disease, but it is subjective and overlaps with normal, especially when the comparison liver is steatotic.
Answer the clinical question first. State whether both kidneys were fully seen. Report lengths, symmetry, echogenicity, hydronephrosis, stones, masses, perinephric fluid, and RI when Doppler was performed. Note incomplete poles or poor Doppler angles. Size and RI do not measure filtration rate, so do not imply function from morphology alone.
A consistent native renal ultrasound answers most morphologic questions when you use reliable windows, measure the true long axis, interrogate the sinus with grayscale and color, and label variants before pathology. Switch to a dedicated protocol for transplant dysfunction or suspected renal-artery stenosis. IAME offers accredited ultrasound CME courses on abdominal and renal imaging. For credit types and license renewal, see ultrasound CME credits.
Frequently Asked Questions
What can a renal ultrasound detect?
A native renal ultrasound can show size and symmetry, cortical thickness and echogenicity, hydronephrosis, many calculi, cysts, solid masses, perinephric collections, and, with Doppler, perfusion and resistive indices. It does not measure glomerular filtration rate and can miss tiny stones, isoechoic tumors, and most main-renal-artery stenoses unless a dedicated vascular protocol is used. Correlate morphology with laboratory data and the clinical question.
Do you get kidney ultrasound results right away?
Images are available as soon as the scan is stored, and a preliminary impression is often possible at the bedside for straightforward findings such as severe hydronephrosis. Final interpretation still requires review of cine clips, measurements, and comparison studies, and turnaround for a signed report varies by practice. Urgent findings should be communicated directly rather than left to the routine report queue.
What is a normal kidney size on renal ultrasound?
In adults, bipolar length is commonly cited in the 9 to 13 cm range, with expected variation by height, sex, and age. A side-to-side difference greater than about 1.5 to 2 cm often prompts a closer look for chronic disease, prior obstruction, or a missed pelvic kidney. Interpret length together with cortical thickness, echogenicity, and the contralateral kidney rather than a single cutoff.
Does renal ultrasound show how well the kidneys are working?
Ultrasound shows structure, perfusion, and secondary signs such as small echogenic kidneys or an elevated resistive index. Those findings can support a diagnosis of parenchymal disease, but they are not a renal function test. Serum creatinine, estimated GFR, and the clinical course remain necessary, and an elevated RI should not be treated as a stand-alone marker of failure.